DelavanPower products for a fluid world.

 

Max Flow:
5830: 3.0 GPM 5840: 4.0 GPM
5836: 3.6 GPM 5850: 5.0 GPM

Max Pressure: 100 PSI

Downloads
Installation Manual (PDF)
PowerFlo Catalog (PDF)

5830
5836
5840
5850

1⁄2" FNPT / Bypass or Demand 3.0 GPM
1⁄2" FNPT / Bypass or Demand 3.6 GPM
1⁄2" FNPT / Bypass or Demand 4.0 GPM
1⁄2" FNPT / Bypass or Demand 5.0 GPM

Specifications


Specifications

Motor Type: 12 VDC permanent magnet, totally enclosed, non-ventilated

Leads: 14 AWG, 12” long

Duty Cycle: See Heat Rise graph

Temperature Limits: Motor is not equipped with thermal protection. For user safety, optimal performance, and maximum motor life, the motor surface temperature should not exceed 180°F (82°C).(See Heat Rise graph)

Materials of Construction

Housings: Polypropylene

Valves: Viton

Diaphragm: Santoprene

Fasteners: Stainless Steel

Motor Shell: Coated Steel

 

 

Pump

Type: 5 chamber positive displacement diaphragm pump, self priming, capable of being run dry, demand or bypass mode

Certifications: NSF Standard 58

Liquid Temperature: 140°F (60°C) Max.

Priming Capabilities: 14 feet (4 m)

Max Pressure: 100 PSI (7 bar)

Inlet/Outlet Ports: 1⁄2” FNPT

Weight:
5830/5836: 6 lbs (2.7 kg)
5840/5850: 8 lbs (3.8 kg)

 

Dimensions Inches (mm)

5830 Bypass

5850 Demand

Performance

5830
5836
PSI
GPM
Amps
GPM
Amps
10
3.20
3.5
3.60
4.0
20
2.80
5.8
3.10
5.9
30
2.65
7.2
2.80
7.5
40
2.45
8.3
2.60
8.9
50
2.20
9.1
2.40
9.7
60
2.00
9.9
2.20
10.5

5840
5850
PSI
GPM
Amps
GPM
Amps
10
4.00
4.8
5.00
6.0
20
3.70
6.1
4.50
9.0
30
3.10
7.7
4.10
11.0
40
2.70
9.6
3.88
13.0
50
2.50
10.8
3.55
14.6
60
2.40
11.3
3.20
16.3

Heat Rise